RS232 specifications, introduction
Communication as defined in the RS232 standard is an
asynchronous serial communication method. The word serial means, that the
information is sent one bit at a time. Asynchronous tells us that the
information is not sent in predefined time slots. Data transfer can start at
any given time and it is the task of the receiver to detect when a message
starts and ends. Asynchronous communication has some advantages and
disadvantages which are both discussed in the next paragraph.
RS232 bit streams
The RS232 standard
describes a communication method where information is sent bit by bit on a
physical channel. The information must be broken up in data words. The length
of a data word is variable. On PC's a length between 5 and 8 bits can be
selected. This length is the netto information length of each word. For proper
transfer additional bits are added for synchronisation and error checking
purposes. It is important, that the transmitter and receiver use the same
number of bits. Otherwise, the data word may be misinterpreted, or not
recognized at all.
With synchronous communication, a clock or
trigger signal must be present which indicates the beginning of each transfer.
The absence of a clock signal makes an asynchronous communication channel
cheaper to operate. Less lines are necessary in the cable. A disadvantage is,
that the receiver can start at the wrong moment receiving the information.
Resynchronization is then needed which costs time. All data received in the
resynchronization period is lost. Another disadvantage is that extra bits are
needed in the data stream to indicate the start and end of useful information.
These extra bits take up bandwidth.
Data bits are sent with a predefined frequency,
the baud rate. Both the transmitter and receiver must be programmed to use the
same bit frequency. After the first bit is received, the receiver calculates at
which moments the other data bits will be received. It will check the line
voltage levels at those moments.
With RS232, the line voltage level can have two
states. The on state is also known as mark, the off state as space. No other
line states are possible. When the line is idle, it is kept in the mark state.
Start bit
RS232 defines an asynchronous type of
communication. This means, that sending of a data word can start on each
moment. If starting at each moment is possible, this can pose some problems for
the receiver to know which is the first bit to receive. To overcome this
problem, each data word is started with an attention bit. This attention bit,
also known as the start bit, is always identified by the space line level.
Because the line is in mark state when idle, the start bit is easily recognized
by the receiver.
Data bits
Directly following the start bit, the data bits
are sent. A bit value 1 causes the line to go in mark state, the bit value 0 is
represented by a space. The least significant bit is always the first bit sent.
Parity bit
For error detecting purposes, it is possible to
add an extra bit to the data word automatically. The transmitter calculates the
value of the bit depending on the information sent. The receiver performs the
same calculation and checks if the actual parity bit value corresponds to the
calculated value. This is further discussed in another paragraph.
Stop bits
Suppose that the receiver has missed the start
bit because of noise on the transmission line. It started on the first
following data bit with a space value. This causes garbled date to reach the
receiver. A mechanism must be present to resynchronize the communication. To do
this, framing is introduced. Framing means, that all the data bits and parity
bit are contained in a frame of start and stop bits. The period of time lying
between the start and stop bits is a constant defined by the baud rate and number
of data and parity bits. The start bit has always space value, the stop bit
always mark value. If the receiver detects a value other than mark when the
stop bit should be present on the line, it knows that there is a
synchronization failure. This causes a framing error condition in the receiving
UART. The device then tries to resynchronize on new incomming bits.
For resynchronizing, the receiver scans the
incomming data for valid start and stop bit pairs. This works, as long as there
is enough variation in the bit patterns of the data words. If data value zero
is sent repeatedly, resynchronization is not possible for example.
The stop bit identifying the end of a data frame
can have different lengths. Actually, it is not a real bit but a minimum period
of time the line must be idle (mark state) at the end of each word. On PC's
this period can have three lengths: the time equal to 1, 1.5 or 2 bits. 1.5
bits is only used with data words of 5 bits length and 2 only for longer words.
A stop bit length of 1 bit is possible for all data word sizes.
RS232 physical properties
The RS232 standard describes a communication
method capable of communicating in different environments. This has had its
impact on the maximum allowable voltages etc. on the pins. In the original
definition, the technical possibilities of that time were taken into account.
The maximum baud rate defined for example is 20 kbps. With current devices
like the 16550A UART, maximum speeds of 1.5 Mbps are allowed.
Voltages
The signal level of the RS232 pins can have two
states. A high bit, or mark state is identified by a negative voltage and a low
bit or space state uses a positive value. This might be a bit confusing,
because in normal circumstances, high logical values are defined by high voltages
also. The voltage limits are shown below.
RS232
voltage values
|
||
Level
|
Transmitter
capable (V) |
Receiver
capable (V) |
Space state (0)
|
+5 ... +15
|
+3 ... +25
|
Mark state (1)
|
-5 ... -15
|
-3 ... -25
|
Undefined
|
-
|
-3 ... +3
|
More information about the voltage levels of
RS232 and other serial interfaces can be found in the interface comparison
table.
The maximum voltage swing the computer can
generate on its port can have influence on the maximum cable length and
communication speed that is allowed. Also, if the voltage difference is small,
data distortion will occur sooner. For example, my Toshiba laptop mark's
voltage is -9.3 V, compared to -11.5 V on my desktop computer. The
laptop has difficulties to communicate with Mitsubishi PLC's in industrial
environments with high noise levels where the desktop computer has no data
errors at all using the same cable. Thus, even far beyond the minimum voltage
levels, 2 volts extra can make a huge difference in communication quality.
Despite the high voltages present, it is not
possible to destroy the serial port by short circuiting. Only applying external
voltages with high currents may eventually burn out the driver chips. Still
then, the UART won't be damaged in most cases.
Maximum cable lengths
Cable length is one of the most discussed items
in RS232 world. The standard has a clear answer, the maximum cable length is
50 feet, or the cable length equal to a capacitance of 2500 pF. The
latter rule is often forgotten. This means that using a cable with low
capacitance allows you to span longer distances without going beyond the
limitations of the standard. If for example UTP CAT-5 cable is used with a
typical capacitance of 17 pF/ft, the maximum allowed cable length is
147 feet.
The cable length mentioned in the standard allows
maximum communication speed to occur. If speed is reduced by a factor 2 or 4,
the maximum length increases dramatically. Texas Instruments has done some
practical experiments years ago at different baud rates to test the maximum
allowed cable lengths. Keep in mind, that the RS232 standard was originally
developed for 20 kbps. By halving the maximum communication speed, the
allowed cable length increases a factor ten!
RS232 cable
length according to Texas Instruments
|
|
Baud rate
|
Maximum
cable length (ft)
|
19200
|
50
|
9600
|
500
|
4800
|
1000
|
2400
|
3000
|
Error detection
One way of detecting errors is already discussed.
It is the frame detection mechanism which is used to test if the incomming bits
were properly surrounded by a start and stop bit pair. For further error
checking, a parity bit can be used. The use of this bit is however not
mandatory. If the existence of wrong bits is rare (when communicating with an
internal modem for example) or if a higher level protocol is used for error
detection and correction (Z-modem, RAS, etc) communication speed can be
increased by not using the parity feature present on the UART.
Parity is a simple way to encode a data word to
have a mechanism to detect an error in the information. The method used with
serial communications adds one bit to each data word. The value of this bit depends
on the value of the data word. It is necessary that both the transmitter and
receiver use the same algorithm to calculate the value of the parity bit.
Otherwise, the receiver may detect errors which are not present.
Even parity
Basically, the parity bit can be calculated in
two ways. When even parity is used, the number of information bits sent will
always contain an even number of logical 1's. If the number of high data bits
is odd, a high value parity bit is added, otherwise a low bit will be used.
Odd parity
The odd parity system is quite similar to the
even parity system, but in this situation, the number of high bits will always
be odd.
Disadvantages of the parity system
The parity system using one bit for each data
word is not capable of finding all errors. Only errors which cause an odd
number of bits to flip will be detected. The second problem is, that there is
no way to know which bit is false. If necessary, a higher level protocol is
necessary to inform the sender that this information must be resent. Therefore,
on noisy lines, often other detection systems are used to assure that the sent
information is received correctly. These systems mostly do not operate on
single data words, but on groups of words. Known coding systems are:
- Hamming coding
- CRC16 cyclic redundancy check
- CCITT-16 cyclic redundancy check
- CRC-DNP cyclic redundancy check
- CRC32 cyclic redundancy check
- RS232 serial cables pinout
- RS232 serial printer cables info
- RS232 serial null modem cable wiring
- RS232 serial spy monitor cable
- RS232 flow control and handshaking
- On-line CRC calculation and free library
- RS232 I.O and IRQ
No comments:
Post a Comment